IconEnglish

Solenoid valve 3/2 NAMUR, monostable, return air spring, manual override, without coil

Article number: MNH310701

Magnet valve without coilMagnet valve without coil2

Solenoid valve 3/2 NAMUR, monostable, return air spring, manual override, without coil

Article number: MNH310701

Documents for Solenoid valve 3/2 NAMUR, monostable, return air spring, manual override, without coil

iconMNH31_701
iconMNH310701
Directly available

excl. VAT incl. VAT

Documents for Solenoid valve 3/2 NAMUR, monostable, return air spring, manual override, without coil

iconMNH31_701
iconMNH310701

All valves are without solenoid coil and standard plug, which must be ordered separately.



3/2-way valves with NAMUR interface

 

A 3/2 NAMUR valve is a pneumatic valve with a special connection pattern of the outputs of the valve. These outputs are normally the ports 2 and 4 of a valve.

 

Thanks to this standard you place the valve directly on the pneumatic actuator with the same NAMUR standard. Hoses and couplings between the valve and the actuator are therefore not required. The pneumatic actuator ensures the opening and closing of, for example, ball valves and butterfly valves.

 

After-hours is used as standard within the process industry or other industrial applications, such as in the pharmaceutical sector, in the chemical industry and in the food industry.

 

NAMUR means "Normen Arbeitsgemeinschaft Für Mess-Und Regelungstechniek". The connections are laid down in the VDI / VDE 3845 standard.

 

 

A 3/2 valve has 3 connection ports and 2 switching positions and can be normally closed or normally open.

 

Normally closed means that ports 1 and 2 are not connected to each other in the position of rest of the valve. Ports 2 and 3 are connected to each other so that any return air can escape.

If you switch the valve, air flows from port 1 to port 2 and the vent port is closed.

 

A normally open valve works the other way around. In the rest position, ports 1 and 2 are connected to each other so that air flows out of the valve when the supply air is connected to port 1. If you switch the valve, port 1 closes and the incoming air can escape via port 3 again.

 

All valves are equipped with a magnetic coil and standard plug.

All statements are intended as non-binding guidelines! We are not liable for data selection not confirmed in writing. Pressure data, unless stated otherwise, relate to liquids from group II at +20 C.

TECHNICAL DATA

Version

Without coil/plug

Version

Monostable

Power consumption

3 W / 5 VA

Operation

Normally closed

Spring

-

Seal

NBR

Material

Aluminium (ALU)

Control

Indirectly

Function

3/2 NC

Thread

G 1/4"

Minimal pressure

2 bar

Maximum pressure

10 bar

Orifice (DN)

1250 L/min.

Minimum temperature

-10 °C

Maximum temperature

60 °C

Voltage

Without coil

Weight
HafnerFHTcmaticVacuproVan deurne